Http Version - Fix to calculate the fill rate.
This commit is contained in:
parent
e1d57eae32
commit
99bc9209af
1 changed files with 1 additions and 1 deletions
|
|
@ -84,7 +84,7 @@ void RequestWorker::requestFinished(QNetworkReply *rep)
|
||||||
float water_level = (float) ((float) (data_water_level) / 10.0);
|
float water_level = (float) ((float) (data_water_level) / 10.0);
|
||||||
float rate_of_fill = ( float )(prev_distance - water_level) /(float) time_in_microseconds;
|
float rate_of_fill = ( float )(prev_distance - water_level) /(float) time_in_microseconds;
|
||||||
rate_of_fill = rate_of_fill * 1'000'000;
|
rate_of_fill = rate_of_fill * 1'000'000;
|
||||||
int expected_to_fill = (max_height - water_level) / rate_of_fill;
|
int expected_to_fill = (water_level - min_height) / rate_of_fill;
|
||||||
if(reply_number == 0) {
|
if(reply_number == 0) {
|
||||||
rate_of_fill = 0;
|
rate_of_fill = 0;
|
||||||
expected_to_fill = 0;
|
expected_to_fill = 0;
|
||||||
|
|
|
||||||
Loading…
Reference in a new issue